Performing primary site storage system maintenance, Failover, Performing primary site storage system – HP XP P9500 Storage User Manual

Page 494

Advertising
background image

Table 112 Using a 4x4x4 Cascade Configuration (continued)

See

Description

Target

Maintenance or
Failure

Number

Consistency
Preservation function,

site storage system”
(page 532)

and then resynchronize
them.

TIP:

The term "storage system failure, with information lost from memory," indicates a failure that

causes the loss of information in memory. In such a failure, the copy pair information and the data
are completely lost, so the hardware information must be reconfigured.

This section provides maintenance and troubleshooting procedures for 3DC Cascade (URxUR)
configurations.

The figures in the procedures in this section use the following legend.

The bullet lists under the figures in the procedures show the commands that must be executed.

Performing primary site storage system maintenance

The following are the procedures for performing primary site storage system maintenance.

Failover

1.

Stop operation at the primary site.

2.

From the intermediate site, execute the YKSUSPND REVERSE command for the Continuous
Access Synchronous Z copy group container.

YKQUERY

YKSUSPND REVERSE

YKEWAIT GOTO(SUSPEND)

494 Maintenance and troubleshooting operations

Advertising