When a bcm monitor instance has started, Bcm monitor operation examples, Backup operation example – HP XP P9500 Storage User Manual

Page 693

Advertising
background image

Table 118 Events and actions to take when a BCM Monitor instance cannot start (continued)

Action

Event

Make sure that the DD statement is
specified correctly, and then restart
BCM Monitor.

The IEC020I message is displayed.

BCM Monitor terminates abnormally
with a system completion code 001.

Take appropriate action according to
the displayed message.

The IEC020I message is not
displayed.

Specify the correct SYSEXEC DD
statement, and then restart BCM
Monitor.

The SYSEXEC DD statement is not
specified.

The following message is displayed:

YK8024E IRXJCL MODULE
ERROR,CODE=20

Check with the system administrator to
determine if the setting for the REXX
execution environment is correct.

The SYSEXEC DD statement is
specified.

Make sure that YKBCMMON is
specified in the PARM operand of the

After being started, BCM Monitor terminates immediately with a return code
00.

EXEC statement, and then restart BCM
Monitor.

Make sure that the format and status of
the specified dataset are correct, and
then restart BCM Monitor.

An I/O error message is displayed.

Take appropriate action according to
the displayed error message.

An error is displayed while analyzing the BCM Monitor parameter files.

Take appropriate action according to
the displayed message.

A message other than those above is displayed.

Take appropriate action according to
the return code.

BCM Monitor terminates with a return code other than 00.

When a BCM Monitor Instance Has Started

Table 119 (page 693)

lists the events and actions to take when a BCM Monitor instance has already

started. In the Event column, go down in the order listed and locate the first description that matches
the event that is occurring, and then use the action in the Action column to solve the problem.

Table 119 Events and Actions to Take When a BCM Monitor Instance Has Already Started

Action

Event

Take appropriate action according to the displayed
message.

An error message is displayed.

Make sure that the user SVC has been registered, and then
restart BCM Monitor.

BCM Monitor has terminated abnormally with a system
completion code Fnn (Fnn: SVC number).

BCM Monitor operation examples

This section provides examples of BCM Monitor operations for backing up data or monitoring the
occurrences of failures.

Backup operation example

This section describes the procedure for using Business Copy to perform daily backups on the
secondary site in a 2DC configuration that uses Continuous Access Journal and Business Copy. In
these examples, the administrator only uses Business Continuity Manager to suspend Continuous
Access Journal copy groups. Subsequent processes are automatically executed by BCM Monitor.

BCM Monitor operation examples 693