F1=Help F3=Exit F7=Backward F8=Forward F12=Cancel

The Command Control Address (CCA) Selection List panel displays the scanning results within
the CU by CCA (device).

Command Control Address (CCA) Selection List Row 1 to 12 of 16
Command ===>

Scroll ===> PAGE

2008/02/26 15:31:47
Device Address Domain : SF
Description . . . : SAN FRANCISCO SAMPLE
Storage System S/N : 14002 Model : USP uCode : 500970FF IFType : 1616
Control Unit . . . : 00
------------------------------------------------------------------------------
SSID CCA Device Number Volume Serial Number Cyls
2340 10- 7310 BCM000 262668
2340 11- 7311 BCM001 262668
2340 12- 7312 BCM002 262668
2340 13- 7313 BCM003 262668
2340 14- 7314 BCM004 262668
2340 15- 7315 BCM005 262668
2340 16- 7316 262668
2340 17- 7317 262668
2340 18- 7318 262668
2340 19- 7319 262668
2340 1A- 731A 262668
2340 1B- 731B 262668

F1=Help F3=Exit F7=Backward F8=Forward F12=Cancel

14. Press the F3=Exit key to save the scan results to a disk configuration definition file.

Disk configuration definition file name: prefix.DSK.SNnnnnn.dad-id.

In the configuration example in

Figure 128 (page 588)

, a disk configuration definition file

named CONFIG01.DSK.SN14002.SF is generated.

Scanning a device locally on the secondary site (local scan)

To scan a volume on the secondary site:
1.

Display the Main Menu panel and choose 1 Set Defaults.

The Set Defaults panel appears.

2.

Specify CONFIG01 (the same prefix as the primary site) in Configuration File Prefix and LA
in Local Device Address Domain ID.

3.

Press the F3=Exit key.

You are returned to the Main Menu panel.

4.

Choose 3 Discover/Define Configuration.

The Discover/Define Configuration panel appears.

5.

Choose 1 Discover HP Storage.

The Discover HP Storage Arrays panel appears. In the initial status, no display line appears.

6.

Press the F4=Discover key.

The Scan Device Address Extent panel appears.

7.

Specify / for Device Num or Volser to set the scan target, and specify the scan range in Start
and End.

8.

Press the F6=Scan key.

The scan result appears.

9.

Repeat steps 7 and 8 to perform a scan with another scope.

Acquiring volume information

591