Recovering, Preparing, Preparing recovering – HP XP P9500 Storage User Manual

Page 373: Operating procedure, During a, Path

Advertising
background image

However, step 1 is different. From the intermediate site, execute the YKDELETE command for the
Continuous Access Journal Z copy pair between the intermediate site and the remote site.

Recovering

For details about the recovering procedure required when a path failure occurs between the storage
systems at the primary site and the intermediate site, see the recovery procedure used when a
failure, with no information lost from memory, occurs in the intermediate site storage system. For
details, see

“Recovering” (page 366)

in

“Operating procedure during an intermediate site storage

system failure (with no information lost from memory)” (page 365)

.

However, there is no need to perform step 2.

Operating procedure during a path failure between the storage systems at the
intermediate site and the remote site

The following are the operating procedures that must be performed when a path failure occurs
between the storage systems at the intermediate site and the remote site.

Preparing

If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same preparatory procedure that is used when a failure, with no information lost from
memory, occurs in the remote site storage system. See

“Preparing” (page 369)

in

“Operating

procedure during a remote site storage system failure (with no information lost from memory)”
(page 369)

.

Recovering

If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same recovery procedure that is used when a failure, with no information lost from
memory, occurs in the remote site storage system. See

“Recovering” (page 370)

in

“Operating

procedure during a remote site storage system failure (with no information lost from memory)”
(page 369)

.

Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration

The following table explains how to perform maintenance for a 3DC Multi-Target (Cnt Ac-J Z x Cnt
Ac-J Z) configuration and how to take action if a failure occurs.

For maintenance or troubleshooting for the primary site storage system, either of the two remote
sites can be selected as the failover destination. If a primary site storage system failure occurred,
you can view the consistency time of each Continuous Access Journal Z copy pair to select the site
that has the latest data update time as the failover destination.

Table 106 Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration

See:

Description

Target

Maintenance
or failure

No.

“Performing
primary site

Create a Continuous Access Journal Z copy
pair between remote sites 1 and 2, and then

Primary site storage system maintenance

Maintenance

1

storage system

change the configuration to a 2DC

maintenance”
(page 376)

configuration (Remote 1

→ Remote 2, or

Remote 2

→ Remote 1).

“Performing
storage system

Suspend the Continuous Access Journal Z
copy pair between the primary site and the

Storage system maintenance for remote site
1 or remote site 2

2

maintenance

maintenance-target remote site, and then

for remote site

change the configuration to a 2DC

1 or 2”
(page 381)

configuration consisting of the primary site
and the other remote site.

Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 373