background image

Table 42 Troubleshooting Problems with the Status of Logical Paths (continued)

Corrective Action

Description

Path Status

Delete DKC command, and then add the path and the
remote storage system again by using the Add Path or
Add DKC command.

Repair the path relay equipment. After that, delete the
path by using the Delete Path or Delete DKC command,

A failure occurs in the path
relay equipment.

and then add the path and the remote storage system
again by using the Add Path or Add DKC command.

Replace the broken cable. After that, delete the path
by using the Delete Path or Delete DKC command, and

The connection cable is
physically broken.

then add the path and the remote storage system again
by using the Add Path or Add DKC command.

Delete the path by using the Delete Path or Delete DKC
command, and then add the path and the remote

Program error is detected.

Program Error

storage system again by using the Add Path or Add
DKC command.

Delete the failed path. You may need to change the
minimum paths setting or delete the remote storage

This path was not established.

<blank>

system in order to delete the path. After the deletion
finishes, add the path and the remote storage system
by using the Add Path or Add DKC command.

Table 43 Troubleshooting Suspended XP Continuous Access Journal Pairs

Corrective Action

Description

Applies To

Suspend
Type

Clear the error condition at the
secondary storage system or secondary

The primary storage system suspended
a pair because the primary storage

Primary
data
volume

PSUE, by
RCU

data volume. If you need to access the

system detected an error condition at

secondary data volume, release the pair

the secondary storage system. The

from the primary storage system. If data

suspend type for the secondary data
volume is by MCU.

in the secondary data volume has been
changed, release the pair from the
primary storage system, and then
re-create the pair by using the Paircreate
window. If data in the secondary data
volume has not been changed, restore
the pair from the primary storage
system.

Check the path status on the DKC Status
window (see

“Troubleshooting Problems

The primary storage system detected an
error during communications with the

Primary
data
volume

PSUE,
S-VOL
Failure

with the Status of Logical Paths”
(page 217)

).

secondary storage system or detected
an I/O error during update copy. In this

Clear any error conditions at the
secondary storage system and the

case, the suspend type for the
secondary data volume is usually by
MCU
.

secondary data volume. If you need to
access the secondary data volume,
release the pair from the secondary
storage system. If data in the secondary
data volume has been changed, release
the pair from the primary storage system
and then re-create the pair by using the
Paircreate window. If data in the
secondary data volume has not been
changed, restore the pair from the
primary storage system.

Restore the pair (pairresync) from the
primary storage system. The primary

The primary storage system could not
find valid control information in its

Primary
data

PSUE,
MCU IMPL

General Troubleshooting

219