05 aprs in action – Kenwood TM-D710GE User Manual

Page 36

Advertising
background image

32

05 APRS in Action

Table 5-2 Configuration Example

Menu Item

Configured Value

LOW SPEED

5

HIGH SPEED

70

SLOW RATE

30 minutes

FAST RATE

120 seconds

Table 5-3 Variable Rate Beaconing Example:

(with LOW SPEED = 5, HIGH SPEED = 70, SLOW RATE = 30 min, FAST RATE = 120 sec)

Speed

TX interval Time

(FAST RATE = HIGH SPEED ÷ Speed)

80

120 seconds (2 minutes)

70

120 seconds (2 minutes)

60

140 seconds (2 minutes and 20 seconds)

50

168 seconds (2 minutes and 48 seconds)

40

210 seconds (3 minutes and 30 seconds)

30

280 seconds (4 minutes and 40 seconds)

20

420 seconds (7 minutes)

10

840 seconds (14 minutes)

5

1680 seconds (28 minutes)

0

1800 seconds (30 minutes)

25

20

35

30

15

10

5

0

10

20

30

40

50

60

70

80

Speed

Speed vs TX Interval Time

TX Interval

Time

(min.)

Fig. 5-4 Speed vs TX Interval Time

Note:

◆ The unit of Speed can be configured by using Menu 626.