Assemble the frame – Goulds Pumps CV 3196 i-FRAME - IOM User Manual

Page 108

Advertising
background image

228A

134

370D

423

370C

Assemble the frame

1. Support the frame assembly in a horizontal position.
2. Check the shaft-end play by moving the shaft forward and backward by hand, and note any indicator

movement.
If the total indicator reading is greater than the values in this table, then disassemble the shaft and
determine the cause.
Use this table as a reference for shaft-end play values.

Table 15: Shaft-end play

Frame

Double row bearing

Duplex bearing

STi inches (millimeters)

0.0011 (0.028)
0.0019 (0.048)

0.0007 (0.018)
0.0010 (0.025)

MTi inches (millimeters)

0.0013 (0.033)
0.0021 (0.053)

0.0009 (0.023)
0.0012 (0.030)

LTi inches (millimeters)

Not applicable

0.0010 (0.025)
0.0015 (0.038)

XLT-i inches (millimeters)

0.0014 (0.036)
0.0023 (0.058)

0.0010 (0.025)
0.0015 (0.038)

SCALE

0.160

3. Check the shaft-sleeve (126) runout.

Maintenance

106

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual

Advertising