Remove the dynamic seal, Remove the frame adapter (mti, lti , xlt-i), Remove the inboard labyrinth oil seal – Goulds Pumps CV 3196 i-FRAME - IOM User Manual
Page 76: Emove the dynamic seal, Emove the frame adapter (mti, lti , xlt-i), Emove the inboard labyrinth oil seal
105
184
106
Remove the dynamic seal
1. Remove the stud nuts (370H).
2. Remove the dynamic-seal assembly.
370H
3. Remove the socket head cap screws (265).
4. Remove the packed stuffing box cover (184) and gasket (264).
5. Remove the repeller (262) from the backplate (444).
444
184
262
264
107
355
106
265
Remove the frame adapter (MTi, LTi , XLT-i)
The 3198 frame adapter is not interchangeable with the adapter of any other model.
1. Remove the dowel pins (469B) and the bolts (370B).
2. Remove the frame adapter (108).
3. Remove and discard the gasket (360D).
You will install a new gasket during reassembly.
Remove the inboard labyrinth oil seal
Labyrinth oil-seal O-rings are part of the 3196 maintenance kits, and they are sold separately.
Maintenance
74
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual