Remove the dynamic seal, Remove the frame adapter (mti, lti , xlt-i), Remove the inboard labyrinth oil seal – Goulds Pumps CV 3196 i-FRAME - IOM User Manual

Page 76: Emove the dynamic seal, Emove the frame adapter (mti, lti , xlt-i), Emove the inboard labyrinth oil seal

Advertising
background image

105

184

106

Remove the dynamic seal

1. Remove the stud nuts (370H).
2. Remove the dynamic-seal assembly.

370H

3. Remove the socket head cap screws (265).
4. Remove the packed stuffing box cover (184) and gasket (264).
5. Remove the repeller (262) from the backplate (444).

444

184

262

264

107

355

106

265

Remove the frame adapter (MTi, LTi , XLT-i)

The 3198 frame adapter is not interchangeable with the adapter of any other model.
1. Remove the dowel pins (469B) and the bolts (370B).
2. Remove the frame adapter (108).
3. Remove and discard the gasket (360D).

You will install a new gasket during reassembly.

Remove the inboard labyrinth oil seal

Labyrinth oil-seal O-rings are part of the 3196 maintenance kits, and they are sold separately.