Goulds Pumps CV 3196 i-FRAME - IOM User Manual

Page 78

Advertising
background image

370D 423

134

361A

168A

496

7. Remove the bearing housing (134) and bearings (112A and 168A) from the shaft (122).

134

112

361A

168A

122

8. Remove the bearing locknut (136) and bearing lock washer (382).
9. Remove the inboard bearing (168A).
10. Remove the outboard bearing (112A).

NOTICE: Use force only on the inner race when you press bearings off the shaft. Do not use force
in situations in which you might break a part. Doing so may result in equipment damage.

NOTICE:
Save the bearings for inspection. Do not reuse the bearings. Doing so may result in decreased
performance.

168

361A

122

112

382

136

Disassemble the power end ( STi and MTi with duplex bearings)

1. Remove the clamp screws (370C) and back off the jam nuts (423).
2. Tighten the jack screws (370D) evenly to move the bearing housing (134) out of the bearing frame

(228A).

3. Remove the shaft assembly from the bearing frame (228A).

Maintenance

76

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual

Advertising