Seal the shaft with a conventional outside-component mechanical seal

WARNING:
The mechanical seal used in an Ex-classified environment must be properly certified. Prior to startup,
make sure that all areas that could leak pumped fluid to the work environment are closed.

NOTICE:
The mechanical seal must have an appropriate seal-flush system. Otherwise, excess heat generation and
seal failure can occur.

1. Assemble the seal chamber.

a) Install the seal-chamber cover or backplate (184) and fasten with nuts (370H).

370H

184

b) Check the seal-chamber cover runout.

Rotate the indicator through 360 degrees. If the total indicator reading is greater than 0.005 in.
(0.13 mm), determine the cause and correct the issue before you proceed.

c) Install the shaft sleeve (126).

Maintenance

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual

115