background image

Temperature and vibration limits

Variable

Limit

Temperature

195°F (91°C)

Vibration

100% increase over the baseline level

Battery life

The i-ALERT Condition Monitor battery is not replaceable. You must replace the entire unit once
the battery runs out of power.
The battery life is not covered as part of the standard five-year pump warranty.
This table shows the average condition monitor battery life under normal and alarm-mode operating
conditions.

Condition monitor operational state

Battery life

Normal operating and environmental conditions

Three to five years

Alarm mode

One year

Nameplate information

Important information for ordering

Every pump has nameplates that provide information about the pump. The nameplates are located on the
casing and the bearing frame.
When you order spare parts, identify this pump information:

• Model
• Size
• Serial number
• Item numbers of the required parts

Refer to the nameplate on the pump casing for most of the information. See Parts List for item numbers.

Nameplate types

Nameplate

Description

Pump casing

Provides information about the hydraulic characteristics of the pump.
The formula for the pump size is: Discharge x Suction - Nominal Maximum Impeller

Diameter in inches.
(Example: 2x3-8)

Bearing frame

Provides information about the lubrication system used.

ATEX

If applicable, your pump unit might have an ATEX nameplate affixed to the pump, the

baseplate, or the discharge head. The nameplate provides information about the ATEX

specifications of this pump.

IECEx

If applicable, your pump unit might have the following IECEx nameplate affixed to the

pump and/or baseplate. The nameplate provides information about the IECEx

specifications of this pump.

Product Description