Part description cv 3196, T description cv 3196 – Goulds Pumps CV 3196 i-FRAME - IOM User Manual
Page 16
Advertising
Part description CV 3196
3196
3796
HT 3196
CV 3196
LF 3196
3198
NM 3196
Casing
Impeller
Cover
Power end
Figure 6: CV 3196 part description
This table describes the pump casing parts.
Table 3: Casing
Part
Description
Discharge
Tangential with optional Connections for venting, flushing, and cleaning out solids.
Gasket
Fully confined
Mounting method
Integral foot support for maximum resistance to misalignment distortion due to
piping loads.
Standard flange
ANSI class 150 flat-face serrated flange
Impeller
The impeller is
• fully open and recessed from the casing
• equipped with curved vanes
• screwed onto the shaft
The threads are sealed from the pumped liquid by a Teflon O-ring.
Product Description
14
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
Advertising