Part description cv 3196, T description cv 3196 – Goulds Pumps CV 3196 i-FRAME - IOM User Manual

Page 16

Advertising
background image

Part description CV 3196

3196

3796

HT 3196

CV 3196

LF 3196

3198

NM 3196

Casing

Impeller

Cover

Power end

Figure 6: CV 3196 part description

This table describes the pump casing parts.

Table 3: Casing

Part

Description

Discharge

Tangential with optional Connections for venting, flushing, and cleaning out solids.

Gasket

Fully confined

Mounting method

Integral foot support for maximum resistance to misalignment distortion due to

piping loads.

Standard flange

ANSI class 150 flat-face serrated flange

Impeller

The impeller is

• fully open and recessed from the casing
• equipped with curved vanes
• screwed onto the shaft

The threads are sealed from the pumped liquid by a Teflon O-ring.

Product Description