Seal-chamber cover removal

Seal-chamber removal procedures

Choose from one of these procedures to remove the seal-chamber cover.

Table 10: Procedures for seal-chamber cover removal by model

Model

Procedure

3196, CV 3196, HT 3196, LF 3196, 3796

Remove the seal-chamber cover.

NM 3196, 3198

Remove the seal-chamber cover and/or backplate.

Remove the seal-chamber cover (3196, CV 3196, HT 3196, LF 3196, 3796)

1. Remove the gland stud nuts (355).
2. Remove the seal-chamber stud nuts (370H).
3. Remove the seal chamber (184).

184

355

250

370H

4. Remove the shaft sleeve (126) if it is used.

The mechanical seal is attached to the sleeve.

NOTICE: Be careful with the stationary portion of the mechanical seal that is either clamped
between the backplate and the gland or seated in the seal-chamber bore. Failure to do so may result in
equipment damage.

5. Remove the rotary portion of the seal from the sleeve by loosening the setscrews and sliding it off the

sleeve.
Refer to the mechanical-seal instructions for more information.

6. Remove the gland (250), the stationary portion of the seal, and the O-ring (360Q).

126

383

360Q

383

250

Maintenance

72