228A

134

370D

423

370C

4. Remove the jack screws (370D) with the nuts (423).

134

236A

496

253B

370D

423

5. Remove the bearing housing O-ring (496).
6. Remove the clamp ring screws (236A) and separate the clamp ring (253B) from the bearing housing

(134).
You must remove the bearings before you can remove the clamp ring from the shaft.

7. Remove the bearing housing (134) and the bearings (112A and 168A) from the shaft (122).

250

184

355

370H

8. Remove the inboard bearing (168A).

Maintenance

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual