1

2

3

4

1.

Annular groove

2.

Pump-side end plate

3.

Driver

4.

Pump half of the coupling guard

The annular groove in the coupling guard half must fit around the end plate.

1

2

3

1.

Annular groove

2.

End plate (pump end)

3.

Guard half

4. Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate. Tighten securely.

1

2

3

1.

Nut

2.

Washer

3.

Bolt

5. Put the driver half of the coupling guard in place:

a) Slightly spread the bottom apart.