Attach the i-alert™ condition monitor to the pump, Attach the i-alert, Condition monitor to the pump – Goulds Pumps CV 3196 i-FRAME - IOM User Manual

Page 120

Advertising
background image

423

370D

370C

5. When you reach a 0.030 in. (0.76 mm) clearance, tighten the clamp bolts (370C), jack bolts (370D),

and lock nuts (423).
This approximates the impeller position when it is set to 0.015 in. (0.38 mm) from the casing. Perform
a final impeller adjustment after you install the impeller into the casing.

6. Check the impeller (101) runout.

Check vane tip to vane tip. If the total indicator reading is greater than 0.005 in. (0.13 mm), determine
the cause and correct the issue before you proceed.
The CV 3196 impeller face is cast, not machined. You do not need to check the face runout.

.030

101

For more information on how to set the impeller clearances, refer to the Impeller-clearance checks and
Impeller-clearance setting sections in Commissioning, Startup, Operation, and Shutdown.

Attach the i-ALERT

Condition Monitor to the pump

CAUTION:
Always wear protective gloves. The pump and condition monitor can be hot.

Maintenance

118

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual

Advertising