Goulds Pumps CV 3196 i-FRAME - IOM User Manual
Page 69
Advertising
1. Is your bearing frame oil lubricated?
• If No: Proceed to step 2.
• If Yes:
1. Remove the bearing-frame drain plug (408A) in order to drain oil from the bearing frame.
2. Replace the plug after the oil is drained.
3. Remove the oil reservoir, if equipped.
408A
NOTICE:
Oil analysis should be part of a preventive maintenance program that determines the cause of a
failure. Save the oil in a clean container for inspection.
Maintenance
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
67
Advertising