b) Place the driver half of the coupling guard over the pump half of the coupling guard.

The annular groove in the coupling guard half must face the motor.

Annular

Driver

Guard half

groove

6. Place the driver-side end plate over the motor shaft.

Driver

End plate

7. Place the driver-side end plate in the annular groove of the driver-half of the coupling guard.
8. Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate. Hand-tighten

only.
The hole is located on the driver-side of the coupling guard half.

9. Slide the driver-half of the coupling guard towards the motor so that the coupling guard completely

covers the shafts and coupling.