Check

Explanation/comment

Checked

Check that the eccentric reducer at the suction

flange of the pump has the following properties:
• Sloping side down
• Horizontal side at the top

See the example illustrations.

If suction strainers or suction bells are used, check

that they are at least three times the area of the

suction piping.

Suction strainers help to prevent

clogging.
Mesh holes with a minimum diameter

of 1/16 in. (1.6 mm) are recommended.

If more than one pump operates from the same

liquid source, check that separate suction-piping

lines are used for each pump.

This recommendation helps you to

achieve a higher pump performance.

If necessary, make sure that the suction piping

includes a drain valve and that it is correctly

installed.

Liquid source below the pump

Check

Explanation/comment

Checked

Make sure that the suction piping is free from

air pockets.

This helps to prevent the occurrence of air

and cavitation in the pump inlet.

Check that the suction piping slopes upwards

from the liquid source to the pump inlet.

If the pump is not self-priming, check that a

device for priming the pump is installed.

Use a foot valve with a diameter that is at

least equivalent to the diameter of the suction

piping.

Liquid source above the pump

Check

Explanation/comment

Checked

Check that an isolation valve is installed in the

suction piping at a distance of at least two

times the pipe diameter from the suction

inlet.

This permits you to close the line during

pump inspection and maintenance.
Do not use the isolation valve to throttle the

pump. Throttling can cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty

Make sure that the suction piping is free from

air pockets.

This helps to prevent the occurrence of air

and cavitation in the pump inlet.

Check that the piping is level or slopes

downward from the liquid source.

Make sure that no part of the suction piping

extends below the suction flange of the

pump.

Make sure that the suction piping is

adequately submerged below the surface of

the liquid source.

This prevents air from entering the pump

through a suction vortex.

Installation

36

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual