Goulds Pumps CV 3196 i-FRAME - IOM User Manual

Page 43

Advertising
background image

Annular

Driver

Driver-side coupling guard

groove

6. Remove the remaining nut, bolt, and washers from the pump half of the coupling guard.

It is not necessary to remove the end plate from the pump side of the bearing housing. You can access
the bearing-housing tap bolts without removing this end plate if maintenance of internal pump parts
is necessary.

7. Remove the pump half of the coupling guard:

a) Slightly spread the bottom apart.
b) Lift upwards.

1

2

3

4

1.

Annular groove

2.

Pump-side end plate

3.

Driver

4.

Pump half of the coupling guard

Commissioning, Startup, Operation, and Shutdown

Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual

41

Advertising