5 hot plug support, Hot plug support, Section 3.5, “hot plug support – MSI X2-109 v1 User Manual
Page 46
 
3-12
MegaRAID BIOS Configuration Utility
Version 2.0
Copyright © 2006 by LSI Logic Corporation. All rights reserved.
4.
When rebuild is complete, the CU displays the message:
Rebuilding of Drive X Completed Successfully. Press Esc.
(X = the ID of the rebuilt drive.)
5.
Press Esc to display the Management Menu.
The state of the rebuilt disk drive changes from FAIL to ONLIN.
If you press Esc while the rebuild is running, the following options 
display:
•
Stop: (Available only if AutoResume is enabled on the adapter: 
Management Menu -> Objects -> Adapter -> AutoResume.) 
The rebuild is stopped, and the CU stores the percentage of the 
rebuild already completed. If AutoResume is enabled, the rebuild 
resumes where it left off when you restart it, instead of starting over 
from 0 percent.
•
Continue: The rebuild continues normally.
•
Abort: The rebuild is completely aborted and the disk drive remains 
in the FAIL state. If you restart the rebuild, it begins at 0 percent.
3.5
Hot Plug Support
The MegaRAID BIOS CU supports hot plugging of disk drives. The 
following hot plug message will appear when you insert or remove a disk 
drive: A Drive Has Been Inserted/Removed. Configuration 
Updated. Press ESC...
After you press Esc the inserted or removed
drive will be reflected in the list of drives that appears in the configuration 
utility.
Obviously, you should not insert or remove a drive while you are defining 
a new logical drive or while an initialization or other process is running. 
The following bullets describe how the CU handles hot plugging when 
various actions occur:
•
If the Physical Drive window or one of the Configuration windows is 
open when you insert or remove a drive, the window will close when 
the hot plug message appears.