7 configuration commands, 1 add raid 0, 1 or 5 configuration, Configuration commands – MSI X2-109 v1 User Manual

Page 61: Add raid 0, 1 or 5 configuration, Add raid 0, 1, or 5 configuration, Section 4.7, “configuration commands

Advertising
background image

Configuration Commands

4-9

Version 2.0

Copyright © 2006 by LSI Logic Corporation. All rights reserved.

4.7

Configuration Commands

You can use the commands in this section to create storage
configurations.

4.7.1

Add RAID 0, 1 or 5 Configuration

Use the command in

Table 4.11

to add a RAID level 0, 1, or 5

configuration to the existing configuration on the selected adapter. For
RAID level 10, see

Section 4.7.3, “Add RAID 10 Configuration.”

Important:

LSI recommends that you do not use both SAS and SATA
drives in the same array. Using different drive interfaces in
this way could cause decreased performance, an increased
error count, and decreased MTBF.

Description

The RAID driver maintains a volatile circular list of 100 events, which is deleted at
reboot. The following command options are available:
• -GetEventlogInfo: Displays overall event information such as total number of

events, newest sequence number, oldest sequence number, shutdown sequence
number, reboot sequence number, and clear sequence number.

• -GetEvents: Gets event log entry details. The information shown consists of the

total number of entries available at the firmware side since the last clear and
details of each error log entry. Start_entry specifies the initial event log entry
when displaying the log.

• -GetSinceShutdown: Displays all the events since last adapter shutdown.
• -GetSinceReboot: Displays all the events since last adapter reboot.
• -IncludeDeleted: Displays all events, including deleted events.
• -GetLatest: Displays the latest number of events, if it exists. The event data is

written to the file in reverse order.

• -Clear: Clears the event log for the selected adapter(s).

Table 4.10

Event Log Management (Cont.)

Table 4.11

Add RAID 0, 1, or 5 Configuration

Syntax

CmdTool –CfgLDAdd -R0|-R1|-R5[E0:Sn] [ -szXXXXXXXX [-szYYYYYYYY
[...]]] [-strpszM] [-Hsp[E5:S5,...]] [–afterLdX] -aN

Advertising