Toshiba Magnia 3310 User Manual

Page 146

Advertising
background image

Installing and Removing Hardware
Hard Disk Drive (HDD)

128

5 Install a new hard disk drive according to the procedure for

installing.
See “Installing the hard disk drive” on page 121.

6 After a short time, confirm that the DC POWER indicator (

)

lights up.

7 If the server is a pedestal model, close the front doors (upper

and lower).

8 Recover (rebuild) the disk array if the RAID controller is

installed.
See “RAID Controller's User’s Guide.”

NOTE: If the server uses a RAID controller for redundancy,
the operation is continued by a spare device without stopping
the system, even if one of the hard disk drives that configure a
disk array fails (downgraded operation). However, if another
device fails, it may destroy and lose important programs or
data. Replace the faulty device by a normal one as quickly as
possible, and recover the disk array.

Advertising