7.7 P
ERIODICAL MAINTENANCE INTERVALS
H
ONDA PETROL ENGINE
* First operation.
** At least every 3 months.
*** At least every 5 years.
# Anyway every year. If the tightening is not correct replace the nuts with two new with the same
specifications and restore the connection without using oil or grease.
As regards complete service of the engine, see the manual supplied by the engine manufacturer or
download it from the website: www.honda‑engines‑eu.com
BOOM LIFT MODELS X14J
JLG
104
X14JR0420113
PART
MAINTENANCE
WORK
BEFORE
STARTING
AS NEEDED
INTERVAL (HOURS)
10
50
100
250
500
1000
2000
AIR FILTER
CHECK, CLEAN
•
REPLACE
•
ENGINE OIL
CHECK LEVEL
•
•
CHANGE
•
*
•
OIL SUMP
CLEAN
•
SFUEL TANK AND
NET
CLEAN
•
HYDRAULIC OIL
CHECK LEVEL
•
CHANGE
•
HYDRAULIC OIL FIL‑
TER
REPLACE CARTRIDGE
•
*
•
ARTICULATED JOINT
POINTS
GREASE
•
*
•
BATTERY
CHECK ELECTROLYTE
LEVEL
•
REDUCTION GEAR
OIL
CHECK LEVEL
•
CHANGE
•
*
•
MASCHINE
GENERAL PERIODICAL
CHECKS
•
•
*
EXTENSION ARM
INTERNAL SLIDING
RING
CHECK WEAR
•
REPLACE
•
TURNTABLE BOLT
TIGHTENING
CHECK
•
*
•
NUT FIXING PINS
BASKET
CHECK TORQUE
200 Nm
•#