JLG X14J Operator Manual User Manual

Page 72

Advertising
background image

THE ENGINE MUST BE STARTED WITH ALL THE CONTROL BUTTONS AND JOY‑
STICKS IN NEUTRAL POSITION.
Always make sure there are no foreign objects (e.g. branches) that may accidentally operate
a control, as the platform may move suddenly out of the operator’s control and cause serious
harm to things and/or people.
Make sure that all the manual controls for the proportional valves are at rest.

6.4.3 S

TARTING THE ELECTRIC MOTOR

Before starting the motor, be clearly aware of all the procedures described in the USER
AND OPERATION MANUAL and get familiar with the meaning of the safety stickers.

Examine the safety rule summary table in the manual
and follow all the instructions given therein.

Power the machine with an electric cable through the
connection positioned at the bottom near the electric
motor.
Close the switch located in the electrical panel near the
motor (see photo).

Before connecting the machine to the main power supply:

Before doing this:

a) Make sure that the specifications of the power line correspond to the voltage and fre‑

quency indicated on the electric motor rating plate.

b) Check the condition of the power cable; it must be sized for a rated power of 2,2 kW. For

connection use a 3x2,5 mm

2

three‑wire cable with F47 ground clamp, double insulation

and 16A plug. The maximum cable length must be 10 m.

c) Place an earth plate in the ground and connect it to the machine’s ground clamp or, if

this is not possible, make sure the power connection is earthed (e.g. indoors).

Make sure that all the emergency STOP buttons are released; This can be seen on the
remote control display by checking the corresponding icon is not shown in position 7. If
the operator attempts to start with an emergency stop button not released, the display
will show an error message when the start button is pressed.

X14JR0420113

68

BOOM LIFT MODELS X14J

JLG

Advertising