OVERLOAD ALARM

If during the basket loading phases the max allowable load is exceeded based on the position
of the jib arm, all movements of the aerial part will be disabled and an error message will be
shown on the display, first on the entire screen and then in position 5.

The alarm will only be reset when the overload is removed. Normal machine operation can
be resumed only then.

B

ASKET LIFTING ALARM

If when using the machine at a height, for whatever reason, the basket is lifted from its posi‑
tion on the load sensor, an alarm prevents all movements of the machine and the display on
the remote control shows an error message.

The alarm is reset only when the basket is fitted back on the load sensor.