JLG X14J Operator Manual User Manual

Page 110

Advertising
background image

7.8

E

LECTRIC MOTOR

The electric motor is located inside of the carriage distributor support cover.

7.8.1 E

LECTRIC MOTOR MAINTENANCE

Periodically check the condition of the following electric motor components.

• P

OWER SUPPLY TERMINALS

Check tightness of the nuts on the power supply terminals and make sure the insulation is
intact.

• F

AN

Keep air intakes clean and make sure the fan can rotate freely.

• B

EARINGS

Check the condition of the bearings, in the event of noise contact JLG for replacement, as the
life of the bearings is reduced significantly in heavy‑duty operating conditions.

Note: this motor is “brushless” therefore no brushes need to be checked or replaced.