3.5 S

TABILISER POSITION MICROSWITCHES

The position of the stabilisers and their contact with the ground are detected by 4 microswit‑
ches positioned near the stabiliser cylinder rod fastening pin.
The microswitches fixed to the stabiliser must be released when the stabiliser rests on the
ground.
Check the correct operation of the microswitches every day.

3.6 J

IB POSITION MICROSWITCH

The position of the jib arm is detected by a microswitch
that is secured to the jib arm itself and works in a slot
made in the jib transmission.

The microswitch must be released when the jib arm is clo‑
sed.

Check the condition and correct operation of the JIB microswitch every day.

3.7 B

ASKET LOAD SENSOR

The load sensor on the basket is made up of a basket sup‑
port with two shafts that only allow the vertical move‑
ment of the basket. The basket support is supplied by the
load cell itself. Two strain gauges are positioned inside
the sensor positioned under the basket and convert the
relative weight inside the basket into an electrical signal.
The electrical signal is then sent to the electronic board,
which processes it and identifies any dangerous condi‑
tions.
The max load depends on the working mode. If the machine works with the jib open, the
load is 120 kg. In case of operation with the jib closed, the maximum load allowed is 200 kg.
The remote control display always shows the maximum load allowed according to the work

X14JR0420113