dangerous.
Avoid leaving the machine in sunny and badly ventilated places for long periods.
The battery pack is connected to the motor control via a 100 A fuse.
The fuse may be replaced only by qualified personnel.
Always keep the battery charged. Recharge the battery pack whenever considered necessary,
even if the battery has not completely run down.
To check the battery level use the special indicator provided. The battery level depends on
many factors, for this reason, to avoid incorrect reading of the indicator, always keep the bat‑
teries charged. If the machine is not used for extended periods, recharge at least every 3
months.

7.23.1 C

OMPONENTS AND DIAGRAMS

BATTERIES
The battery pack must be used and handled with care to ensure safe operation and maxi‑
mum machine performance.
The battery pack has a rated voltage of 48 Vdc; any modifications made by unauthorised per‑
sonnel invalidate the warranty and may cause damage to the machine and harm to people
and things.
Only Jlg technical personnel are authorised to handle and access the battery pack.
The battery pack is made up of just one module positioned at the rear of the machine. The
weight of the battery pack is approximately 80 kg.
BATTERY REPLACEMENT & MAINTENANCE

In case of problems, only qualified personnel are authorised to access the battery pack and
replace it.
RECHARGING
Recharge the Jlg Battery System only using the special battery charger provided with the
machine.

Using a different battery charger may cause damage to things and people.
Do not remove the cover and do not tamper with the battery charger.
Failure to observe these rules voids the machine’s warranty, may affect the correct operation
of the battery system and may cause damage to the machine and pose a risk to the operator.
Recharge the machine in a ventilated and dry place, at an external temperature not excee‑
ding 40°C and not below 0°C.
Always supervise the machine when recharging.

To recharge the machine, proceed as follows:
− Connect the main power cable (220V ~) to the socket on the side of the undercarriage distri‑
butor support.