Best way how to connect PRIGW unit into your telecomm. site:








Connection with 2x PRI BOARD (connection to PSTN <> PBX trunk):







Connection between two PRI equipments
In case that system is switched off or has some SW problem (uploading firmware), switches on PRI board

automatically disconnect PRIGW and makes direct connection between your switch and PSTN network.


* port mode (NT, TE) and Synchronization (MASTER, SLAVE) must be different on the switch than on the

PRIGW! TEI management number must be same on both equipment units!

Your
switch

PRIGW
unit

Port:

NT

Synchronization:

MASTER

TEI :

0

Port PRI 1:

TE

Synchronization:

SLAVE

TEI :

0

EuroISDN, Q.931 EDSS1

Fig.: contacts of TE connectors

Fig.: contacts of NT connectors

6 Tx

5 Rx

4 Rx

3 Tx

2 nepoužit

1 nepoužit

8

7

6

3

2

1

8 nepoužit

7 nepoužit

5

4

6 Rx

5 Tx

4 Tx

3 Rx

2 nepoužit

1 nepoužit

8

7

6

3

2

1

8 nepoužit

7 nepoužit

5

4

1 RX

2 RX

3 Not used

4 TX

1 TX

3 Not used

7 Not used

8 Not used

5 TX

7 Not used

8 Not used

4 RX

5 RX

6 Not used

2 TX

6 Not used

Pair 1

Pair 2

3

Pair 4

Your
Switch

PRIGW
unit

Port:

TE

Synchronization:

SLAVE

TEI :

0

EuroISDN, Q.931 EDSS1

Port PRI 1:

NT

Synchronization:

MASTER

TEI :

0

PSTN
network

Port PRI 2:

TE

Synchronization:

SLAVE

TEI :

0

Port:

NT

Synchronization:

MASTER

TEI :

0

Advertising