2N PRI Gateways - User Manual User Manual

Page 67

Advertising
background image

!! Preliminary version of user guide v1.8 !!

!! Preliminary version of user guide v1.8 !!

65


9.7.3.2

ISDN parameters

PRI ISDN connection settings.

ISDN
- ISDN PRI 1 port type -
defines the type of the PRI 1 ISDN port on the PRIGW PRI ISDN board.
ISDN PRI is a point-to-point connection. The gateway must have an opposite port type than the
device it is connected to

*.

PRI 1 port is always set as internal – there is activated LCR function, PRI 2 port is always set as
external – all calls from PRI 2 port will be rerouted to PRI 1 port. PRI 2 port has ALWAYS opposite
mode than PRI 1 port !!


- Synchronization –
selects the device to transmit the synchronization clock.

-

Master – the gateway sends the synchronization clock, the connected device must
be set to receive the synchronization clock.

-

Slave – the gateway receives the synchronization clock from the connected
device.


- TEI management –
gateway identification address (0 by default, 62 max.)

- Channel number select –
defines way of occupation of B-channels on PRI interface

- Upward > gateway will occupy channels from channel 1 to 32

- Downward > gateway will occupy channels from channel 32 to 1