2N PRI Gateways - User Manual User Manual
Page 66

64
-
Number for remote control: number for remote control via DATA B-channel (this feature is
optional)
-
Automatic log-out of GSM modules : This function is used for automatic log out of
modules in selected time. If logged in modules are occupied by a call, the logged out
modules log again in to the net automatically. If the traffic decreases, the modules log out
again from the network at random intervals
- Enable automatic logout – Permission / prohibition of this function.
- Logout Hour –The time when modules start to log out randomly from the GSM
network
- Login Hour – The time when the modules start to log in again to the GSM network
- Min. logged-in modules – The minimal number of GSM modules that remain logged in.
-
Automatically move to summer/winter time – for automatic switch summer/winter time
-
Gateway will be configured as – By this parameter you can set which protocol will be
activated in the gateway. ISDN-DSS1 must be activated in case that in the gateway is PRI ISDN
board. VoIP-SIP is for gateway with VoIP board.