7. Installation

7.1. Firmware version and license

Before installation of your PRIGW Gateway please make upload of new FW to the

gateway. Actual version of the firmware + all software you find on enclosed CD, or on our
website

www.2N.cz

.

FIRMWARE uploading procedure (by local serial port):

Connect your PC to PRIGW (COM1) via RS232 (serial port).
Prepare the firmware-containing file into a folder selected by you (Pxxxx-V-xx.xx.xx.hex).
Run PRIGW program
In the section “Gateway control” choose item “Firmware/Licence”
Choose file in “Firmware file” containing new firmware (Pxxxx-V-xx.xx.xx.hex)
Click on button “Upgrade firmware trough COM”.
The program now automatically uploads your new firmware (it’s takes about 2 minutes)

– the gateway is reset during this procedure (thus discontinues all current calls and
SMS). Do not interrupt the program during this procedure to avoid errors in firmware
uploading – otherwise the gateway might stop working!

If procedure of uploading firmware was terminated, please make cool reset of the gateway

and re-load PRIGW program and try to upload firmware again.

FIRMWARE uploading procedure (remotely by ethernet)*:

- Run PRIGW program
- In section “Gateway control” choose item “Firmware/Licence”
- Choose file in “Firmware file” containing new firmware (Pxxxx-V-xx.xx.xx.hex)
- Click on button “Upgrade firmware trough Ethernet”.
- The program now automatically uploads your new firmware (it’s takes about 30 seconds)

the gateway is reset during this procedure (thus discontinues all current calls and
SMS). Do not interrupt the program during this procedure to avoid errors in
firmware uploading – otherwise the gateway might stop working!

*for successful firmware upgrade trough Ethernet you have to :

- grant remote upgrade in configuration of the gateway.

- gateway must contains bootware v02.52 or higher and firmware v02.30.01 or higher

- gateway (CPU) must be connected to Ethernet network.

Firmware license:

The gateway’s firmware is from factory limited for

850 hour* (c. 35 days, every reset of gateway

will add one hour !). After this time the gateway will block the Layer 3 (signalization layer) on the
PRI interfaces !!!
Actual status of limit you can see in status line of connected PRIGW program.
Please contact 2N sales before end of this period. We will send to you new licence key string for
unlock licence limitation of the firmware.

How to add new licence:

-

Connect your PC to PRIGW via RS232, ISDN DATA, TCP/IP

-

Make cool reset of the gateway