AirLive SNMP-24MGB User Manual
Page 227
5. CLI Management in SNM-24MGB
AirLive SNMP-24MGB v2 User’s Manual
220
set applicant
Syntax
:
set applicant <port> < 0 | 1 >
Description
:
To set default applicant mode for each port.
Argument
:
<port>: port range, syntax 1,5-7, available from 1 to 24
<0>: set applicant as normal mode
<1>: set applicant as non-participant mode
Possible value:
<port>: 1 to 24
< 0 | 1 >: normal or non-participant
Example:
SNMP-24MGB(gvrp)# set applicant 1-10 non-participant
set registrar
Syntax
:
set registrar <port> < 0 | 1 | 2>
Description
:
To set default registrar mode for each port.
Argument
:
<port>: port range, syntax 1,5-7, available from 1 to 24
<0>: set registrar as normal mode
<1>: set registrar as fixed mode
<2>: set registrar as forbidden mode
Possible value:
<range>: 1 to 24
< 0 | 1 | 2>: normal or fixed or forbidden
Example:
SNMP-24MGB(gvrp)# set registrar 1-5 fixed