Stop > 60.00 hz, Stop > 0% load, Stop > 0 vac – Lenze MC3000 Series User Manual
Page 29
![background image](/manuals/566095/29/background.png)
13435743_EDBM301_v14 .0
25
13 .2
MC3000 DISPLAY
The following describes the possible display configurations for the MC3000 Series drive
when operating as a standard drive (without PID control) . Refer to Section 19 - MC3000
PID SETPOINT CONTROL for a complete description of drive operation when using
PID control .
13 .2 .1 MC3000 DISPLAY IN STOP MODE
When the drive is in the STOP mode, there are three possible displays . The first is the
SPEED display, which looks like this:
STOP > 60.00 HZ
DRIVE
STATUS
SPEED
SETPOINT
SPEED
UNITS
DIRECTION
(FORWARD)
NOTE
Refer to Parameter 31 - UNITS for the SPEED UNITS display options .
Pressing the ENTER key will change the display from the SPEED indication to the %
LOAD indication:
STOP > 0% LOAD
DRIVE
STATUS
PERCENT
LOAD
DIRECTION
(FORWARD)
Pressing the ENTER key again will change the display from the % LOAD indication to
the VAC (motor voltage) indication:
STOP > 0 VAC
DRIVE
STATUS
MOTOR
VOLTAGE
DIRECTION
(FORWARD)
Pressing ENTER again will change the display back to the SPEED indication .