17 parameter menu parameter menu – Lenze MC3000 Series User Manual

Page 44

Advertising
background image

40

13435743_EDBM301_v14 .0

17

PARAMETER MENU

PARAMETER MENU

PARAM .

NUMBER

PARAMETER

NAME

RANGE OF

ADJUSTMENT

FACTORY

DEFAULT

0

LINE VOLTS

HIGH

LOW

AUTO

AUTO

1

SPEED #1

MIN FRQ - MAX FRQ

20 .00 Hz

2

SPEED #2

MIN FRQ - MAX FRQ

20 .00 Hz

3

SPEED #3

MIN FRQ - MAX FRQ

20 .00 Hz

4

SPEED #4

MIN FRQ - MAX FRQ

20 .00 Hz

5

SkIP #1

0 .00 Hz - MAX FRQ

0 .00 Hz

6

SkIP #2

0 .00 Hz - MAX FRQ

0 .00 Hz

7

BAND WID

0 .00 - 10 .00 Hz

1 .00 Hz

8

ACCEL

(NOTE 1)

30 .0 SEC

9

DECEL

(NOTE 1)

30 .0 SEC

10

MIN FRQ

0 .00 - MAX FRQ

.50 Hz

11

MAX FRQ

MIN FRQ - 120 .0 Hz

60 .00 Hz

12

DC BRAkE

(NOTE 1)

0 .0 VDC

13

DC TIME

0 .0 - 999 .9 SEC

0 .0 SEC

14

DYN BRAkE

OFF

ON

OFF

16

CURRENT

25 - 180 % (NOTE 2)

180%

17

MOTOR OL

25 - 100 %

100%

18

BASE

20 .00 - 360 .0 Hz

60 .00 Hz

19

FX BOOST

0 .0 - 30 .0 %

(NOTE 1)

22

TORQUE

CONSTANT

VARIABLE

CT / NOCMP

CONSTANT

23

CARRIER

2 .5, 6, 8, 10, 12, 14 kHz

2 .5 kHz

25

START

NORMAL

POWER UP

AUTO 1

AUTO 2

AUTO 3

NORMAL

26

STOP

COAST

RAMP

RAMP2

COAST

NOTE 1:

Refer to SECTION 18 - DESCRIPTION OF PARAMETERS

NOTE 2:

If line volts is set to "LOW" (or set to "AUTO" and the input voltage is

low), the range is 25 - 150% .

Advertising