MC3000 MODEL DESIGNATION CODE

The model number of an MC3000 Series drive gives a full description of the basic drive
unit (see example below) .

EXAMPLE: M3450BP
(MC3000, 480 Vac, 5 HP, Type 1 Enclosure, with a Remote keypad Assembly)

M3 4 50

B

P

Series:

M3 = M3000 Series Variable Speed AC Motor Drive

Input Voltage:

1 = 240/120 Vac (For 110, 115, 120, 230 and 240 Vac; 50 or 60 Hz)
2 = 240/200 Vac (For 208, 230, and 240 Vac; 50 or 60 Hz)
4 = 480/400 Vac (For 380, 415, 440, 460 and 480 Vac; 50 or 60 Hz)
5 = 590/480 Vac (For 440, 460, 480, 575 and 600 Vac; 50 or 60 Hz)

Rating:

03 = ¼ HP (0 .18 kW) 50 / 51 = 5 HP (3 .7 kW)

300 = 30 HP (22 kW)

05 = ½ HP (0 .37 kW)

75 = 7½ HP (5 .5 kW)

400 = 40 HP (30 kW)

10 = 1 HP (0 .75 kW)

100 = 10 HP (7 .5 kW)

500 = 50 HP (37 .5 kW)

15 = 1½ HP (1 .1 kW)

150 = 15 HP (11 kW)

600 = 60 HP (45 kW)

20 = 2 HP (1 .5 kW)

200 = 20 HP (15 kW)

30 = 3 HP (2 .2 kW)

250 = 25 HP (18 .5 kW)

Input Phase:

S

= Single phase input only .
No character indicates three phase input only

Enclosure Type:

A = Chassis - Open Enclosure with Cover Removed

B = NEMA 1 - General Purpose, vented

C = NEMA 4 - Water-tight and Dust-tight

D = NEMA 12 - Oil-tight and Dust-tight

E = NEMA 4X - Water-tight, Dust-tight, and Corrosion Resistant (Stainless Steel)

Standard Options:

H = Additional Form C Relay circuit board

J = Dynamic Braking circuit board

k = Dynamic Braking & Additional Form C Relay board (not available on all HP sizes - consult factory)

No character when this type of option is not specified

Interface Options:

P = Remote keypad assembly

No character when this type of option is not specified