Lenze MC3000 Series User Manual

Page 67

Advertising
background image

13435743_EDBM301_v14 .0

63

63

SOFTWARE

(SOFTWARE VERSION)

This parameter displays the software code and revision number of the control board

software . This information is useful when contacting the factory for programming or

troubleshooting assistance . This is a “view-only” parameter, and cannot be changed .

64

MONITOR (MONITOR)

This parameter is used to enable (ON) or disable (OFF) the MONITOR MODE function .

The functionality is explained below:

ON

Pressing the PROG/RUN key will activate the PASSWORD

prompt . If the ENTER key is pressed while the password value

reads 0000, the MONITOR MODE is entered and parameters

can be viewed (except for PASSWORD), but not changed .

OFF

Pressing the PROG/RUN key will activate the PASSWORD

prompt . If the ENTER key is pressed while the password value

reads 0000, it will be treated as in incorrect password and the

display will flash ERROR: INCORRECT, and then return to the

PASSWORD prompt to allow another attempt at entering the

correct password .

65

PROGRAM

(PROGRAM FACTORY DEFAULTS)

WARNING!
EXTERNAL FAULT (TB-13D) circuitry may be disabled if parameters

are reset to factory defaults! The drive must be reprogrammed after

a RESET in order to insure proper operation .
FAILURE TO DO SO MAY RESULT IN DAMAGE TO EQUIPMENT

AND/OR INJURY TO PERSONNEL!

This parameter is used to reset the programmable parameters back to the factory default

settings . This parameter has three possible settings:

MAINTAIN

Maintain parameter settings as they are .

RESET 60

Resets parameters to factory defaults for 60 Hz base frequency .

RESET 50

Resets parameters to factory defaults for 50 Hz base frequency .

NOTE 1:

This parameter will display RESET 60 or RESET 50 until a change is made

to one or more of the parameter settings . Once a parameter is changed, the

display will change to MAINTAIN .

NOTE 2:

When a reset is performed, TB-13D will default to a normally open

EXTERNAL FAULT contact because Parameter 50 - TB13D will be reset
to EXT FAULT .

66

HISTORY

(CLEAR FAULT HISTORY)

This parameter is used to clear the previous faults in the FAULT HISTORY . When set

to CLEAR and the ENTER key is pushed, the display will change to MAINTAIN, and the

FAULT HISTORY will display NO FAULT for each of the eight fault histories .

Advertising