Scope of supply

Position

Description

Number

Power supply module ECSEExxx

1

Accessory kit with attachment material

1

Mounting instructions

1

Drilling jig

1

Note!

The ECSZE000X0B connector set must be ordered separately.

Connections and interfaces

Position

Description

Detailed

information

X22

Connections

External brake resistor

DC-bus voltage

PE



87

LEDs: Status and fault display

X1

Automation interface (AIF) for

Communication module

Operating module (XT keypad)



101

X2

PE connection AIF

X3

Not assigned

X4

CAN connection

System bus (CAN)

Interface for

– master control and other modules

– PC/HMI for parameterisation and diagnostics



102

X6

Connections

Low-voltage supply

Digital inputs and outputs

Thermostat contacts



100

S1

DIP switch

CAN node address (device address in the CAN network)

CAN baud rate

X21

Mains connection



84

Status displays

LED

Description

Red

Green

Off

On

Power supply module is enabled, no fault

Off

Blinking

Power supply module is inhibited (CINH), switch-on inhibit

Blinking, 1 Hz

Off

Fault / error (TRIP) / short-circuit braking error (KSB-TRIP) is active

Blinking, 3 Hz

Off

Message active

Blinking, 1 Hz

Blinking

Warning active with inhibited module

Blinking, 1 Hz

On

Warning active with enabled module

Advertising