Electrical installation – Lenze ECSEExxx User Manual

Page 90

Advertising
background image

Electrical installation

Power terminals

Connection plan for mimimum wiring with internal brake resistor

4

90

EDKCSEE040 DE/EN/FR 4.0

L3

N

L1

L2

Z1

K1

K1

L1

L2

L3

PE

X21

+UG

+UG +UG

-UG

-UG

-UG

PE

PE

PE

X22

X23

Off

On

+UG

BR1

BR0

M

3~

R

T1

T2

X6

...

J

2

6

K1

0

Rb

U

V

W PE

X24

BD1 BD2

X25

X7

"

"

+

"

"

+UG +UG

-UG

-UG

PE

PE

X23

M

3~

R

J

2

6

0

U

V

W PE

X24

BD1 BD2

X25

X7

+

"

"

"

"

F4

F1...F3

"
"

ECSxS/P/M/A...

ECSEE...

ECSDE...

ECSxS/P/M/A...

ECSXA011

Fig. 4-3

Interconnected power system with internal brake resistor

HF-shield termination by large surface connection to functional earth (see

mounting instructions for shield mounting ECSZS000X0B)
Twisted cables

K1

Mains contactor

F1 ... F4

Fuse

Z1

Mains choke / mains filter, optional

Rb

Internal brake resistor

KTY thermal sensor of the motor

System cable for feedback

Advertising