Electrical installation – Lenze ECSEExxx User Manual

Page 99

Advertising
background image

Electrical installation

Control terminals

4

99

EDKCSEE040 DE/EN/FR 4.0

Assignment of the plug connectors

Terminal strip X6
View

Terminal

Function

Electrical data

T1

DO1

DI2

DI1

T2

D24

GND

+24

X6/+24

Low-voltage supply of control

electronics

20 ... 30 V DC, 0.5 A (max. 1 A)

for 24 V starting current:

max. 2 A for 50 ms

X6/GND

Reference potential low-voltage

supply

X6/T1

Thermostat contact 1

X6/T2

Thermostat contact 2

X6/D24

Low-voltage supply X6/DO1

(digital output 1)

18 ... 30 V DC

X6/DO1

Digital output 1

(for central controller enable

signal to connected axis

modules)

24 V DC, 0.7 A (max. 1.4 A)

short-circuit-proof

X6/DI1

Digital input 1

(for power supply enable/charge

of the DC bus)

LOW:

-3 ... +5 V;

-3 ... +1.5 mA

HIGH:

+15 ... +30 V;

+2 ... +15 mA

Input current at 24 V DC:

8 mA per input

X6/DI2

Digital input 2

(for central controller enable

signal to connected modules;

available at output X6/DO1)

Cable cross-sections and screw-tightening torques

Cable type Wire end ferrule

Cable cross-section Tightening torque

Stripping length

Flexible

Without wire end

ferrule

0.08 ... 1.5 mm

2

(AWG 28 ... 16)

0.22 ... 0.25 Nm

(1.95 ... 2.2 lb-in)

5 mm for screw

connection

9 mm for spring

connection

With insulated wire

end ferrule

0.25 ... 0.5 mm

2

(AWG 22 ... 20)

We recommend to use control cables with a cable cross-section of 0.25 mm

2

.