Assembly instructions han, K 4/4 / han, K 6/12 / han – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual

Page 134: K 6/6 / han, K 8/0, Assembly instructions, K 4/4

Advertising
background image

05

.

22

Han

Com

Assembly instructions

Han

®

K 4/4

Description

Depiction

Dimensions in mm

Step 1:

Signal contacts:

Push screwdriver (0.5 x 3.5) into rectangular

chamber. Strip insulation from the wire with

a length given on page 05.06 and insert the

wire into the round contact chamber.

Power contacts:

Strip insulation from the wire with a length

given on page 05.06 and insert the wire into

the contact chamber until insulation is flush

with contact.

Do not twist the strands of the wire.

l: Stripping length for signal contacts
L: Stripping length for power contacts

Step 2:

Signal contacts:

Push screwdriver (0.5 x 3.5) out of rectangu-

lar chamber.

Power contacts:

Hold the wire in position and tighten by a he-

xagonal driver (SW 2.5) from the mating side

with a tightening torque given on page 05.06.

Step 3:

Complete connection

The male insert is shown. The same method is applicable for female inserts.