Assembly instructions han, K 4/4 / han, K 6/12 / han – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual
Page 134: K 6/6 / han, K 8/0, Assembly instructions, K 4/4
05
.
22
Han
Com
Assembly instructions
Han
®
K 4/4
Description
Depiction
Dimensions in mm
Step 1:
Signal contacts:
Push screwdriver (0.5 x 3.5) into rectangular
chamber. Strip insulation from the wire with
a length given on page 05.06 and insert the
wire into the round contact chamber.
Power contacts:
Strip insulation from the wire with a length
given on page 05.06 and insert the wire into
the contact chamber until insulation is flush
with contact.
Do not twist the strands of the wire.
l: Stripping length for signal contacts
L: Stripping length for power contacts
Step 2:
Signal contacts:
Push screwdriver (0.5 x 3.5) out of rectangu-
lar chamber.
Power contacts:
Hold the wire in position and tighten by a he-
xagonal driver (SW 2.5) from the mating side
with a tightening torque given on page 05.06.
Step 3:
Complete connection
The male insert is shown. The same method is applicable for female inserts.