Staf, Features – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual

Page 155

Advertising
background image

09

.

02

Staf

Staf

®

Features

• Degree of protection for hoods/housings for coupled

connector: IP 44

Current carrying capacity

The current carrying capacity of the connectors is limited by the

thermal load capability of the contact element material including

the connections and the insulating parts. The derating curve

is therefore valid for currents which flow constantly (non-inter-

mittent) through each contact element of the connector evenly,

without exceeding the allowed maximum temperature.

Measuring and testing techniques according to

DIN EN 60 512-5-2

Operating current

Ambient temperature

➀ Staf

®

6

➁ Staf

®

14

➂ Staf

®

20

Features

Specifications

DIN EN 60 664-1

DIN EN 61 984

Approvals

,

Inserts

Number of contacts

6, 14, 20, 40 (2x20)

Electrical data acc. to EN 61 984
Rated current

10 A

Rated voltage

∼ 25 V / − 60 V

Rated voltage

acc. to UL/CSA

50 V

Insulation resistance

≥ 10

10

Ω

Material

polyamide

Limiting temperatures

-40 °C ... +100 °C

Flammability acc. to UL 94

HB

Mechanical working life

- mating cycles

≥ 500

Contacts

Material

copper alloy

Surface

- hard-silver plated

3 µm Ag

Contact resistance

≤ 2 mΩ

Screw terminal

- Wire gauge

1)

P P t

- AWG

16

- Tightening/test torque

0.25 Nm

Solder terminal

- Wire gauge

1)

P P t

- AWG

14

In accordance with the appropriate regulations a wire-end sleeve

has to be used at clamps without wire protection (see „Screw

Hoods/Housings

see chapter 31

Accessories

Cable clamps

chapter 95

Coding of hoods/housings

chapter 95

Label acc. to CSA-approval

chapter 95

1)

geometric wire gauge