05.
23
Han
Com
Assembly instructions
Han
®
K 6/12
Description
Depiction
Dimensions in mm
Step 1:
Signal contacts:
Strip insulation from the wire with a length
given on page 05.10 and insert the wire into
the rectangular contact chamber.
Power contacts:
Strip insulation from the wire with a length
given on page 05.10 and insert the wire into
the contact chamber until insulation is flush
with contact.
Do not twist the strands of the wire.
l: Stripping length for signal contacts
L: Stripping length for power contacts
Step 2:
Signal contacts:
Tighten screw termination with screwdriver
(0.5 x 3.5) with a tightening torque given on
page 05.10.
Power contacts:
Hold the wire in position and tighten by a
hexagonal driver (SW 2) from the mating side
with a tightening torque given on page 05.10.
Step 3:
Complete connection
The male insert is shown. The same method is applicable for female inserts.