Han-power® s with 1x han® q 4/2, metal, Han-power, S with 1x han – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual

Page 281: Q 4/2, metal, Q 4/2, metal features, Description, Technical characteristics

Advertising
background image

15

.

16

Power

Distribution

Han-Power

®

S with 1x Han

®

Q 4/2, metal

Features

• 6 IDCs/screw terminals + PE for 4 mm² up to 6

mm² wire gauge; 4 IDCs + PE for 10 mm² wire

gauge

• No interuption of the energy supply

• Space-saving and compact design

• Leading protective ground within the insert

• Assembly with standard tools

Description

Han-Power

®

S metal version allows the realisation of appli-

cations where a high degree of protection is required against

dust, splashed water and mechanical shock. This new variant

continues to support the user in providing simple installation

and maintenance practices but now offers greater protection

against harsh industrial environments.

Han-Power

®

S metal offers optimal handling characteristics

and now features an increased wire gauge range. It is now

possible to realise power distribution networks with wire gauge

up to 10 mm².

This power supply has to be realized with one Han-Compact

®

hood.

Current carrying capacity

The current carrying capacity of the connectors is limited by the

thermal load capability of the contact element material including

the connections and the insulating parts. The derating curve

is therefore valid for currents which flow constantly (non-inter-

mittent) through each contact element of the connector evenly,

without exceeding the allowed maximum temperature.

Measuring and testing techniques according to

DIN EN 60 512-5-2

Operating

current

Ambient temperature

➀ Han

®

Q 4/2 Wire gauge: 4 mm²

➁ Han

®

Q 4/2 Wire gauge: 6 mm²

Han

®

Q 4/2 fully loaded

with wire gauge 4x 6 mm²

Technical characteristics

Specifications

DIN EN 61 984

DIN EN 60 664-1

Han-Power

®

S

Number of contacts

- Power contacts

4 + PE

- Signal contacts

2

Electrical data

acc. to EN 61 984

Power side

40 A 400/690 V 6 kV 3

Rated current

40 A

Rated voltage conductor - ground 400 V

Rated voltage conductor - conductor 690 V

Rated impulse voltage

6 kV

Pollution degree

3

Signal side

10 A 250 V 4 kV 3

Rated current

10 A

Rated voltage

250 V

Rated impulse voltage

4 kV

Pollution degree

3

Rated voltage

acc. to UL/CSA

600 / 250 V

Insulation resistance

≥ 10

10

Material

aluminium die-cast

Limiting temperatures

-40 °C ... +125 °C

Flammability acc. to UL 94

V 0

Mechanical working life

- mating cycles

≥ 500

Degree of protection acc. to DIN EN 60 529 IP 65

Contacts

Material

copper alloy

Surface

- hard-silver plated

3 µm Ag

- hard-gold plated

2 µm Au over 3 µm Ni

Contact resistance

≤ 0.3 mΩ

Crimp terminal

- mm²

4 ... 10 mm² /

0.14 ... 2.5 mm²

- AWG

12 ... 8 / 26 ... 14

Max. insulation diameter

- Power contacts

5 mm

Cables

Design of conductor acc. to

DIN VDE 0281

DIN EN 60 228

Single strand

Wire gauge

4 mm²

- Number of single strands

56 x 0.3 mm ∅

- Outer diameter

4.2 mm

Wire gauge

6 mm²

- Number of single strands

84 x 0.3 mm ∅

- Outer diameter

4.8 mm

Wire gauge

10 mm²

- Number of single strands

80 x 0.4 mm ∅

- Outer diameter

6.3 mm

Advertising