Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual
Page 461
42.
07
Han
GND
Han
®
GND
↺
↺
Assembly and construction
Protection against unintentional opening
1.
Push the unlocking protection over the
opening latches to prevent an unintentional
opening (the connector can only be unma
ted with a separate tool).
2.
The removal of the unlocking protection
can be done with a screwdriver for slotted
screws (e.g. size 0.8 x 4.0). Insert the
screwdriver in the unlocking protection slot
and release the plastic latch until you are
able to remove the unlocking protection
with your fingers.
3.
Insert the installed cable through the cable
gland into the Han
®
GND housing!
Push the axial screw contact into the
module until you hear an audible click,
which is the indicator that the contact
snaps into position.
4.
Push the module back into the housing
and turn the cable gland clockwise.
5.
Mount the module in the housing with the
enclosed screws.