RKI Instruments Eagle Series User Manual

Page 25

Advertising
background image

20 • Alarms

Diffusion Eagle Instruction Manual

STEL alarm (toxics only)

If a toxic gas channel’s average gas reading for the past 15 minutes exceeds
the STEL alarm setting:

STEL displays in the alarm field for that channel.

The channel’s display line flashes.

The buzzer sounds a pulsed tone.

The alarm lights flash.

TWA alarm (toxics only)

If a toxic gas channel’s average gas reading for the past 8 hours exceeds the
TWA alarm setting:

TWA displays in the alarm field for that channel.

The channel’s display line flashes.

The buzzer sounds a pulsed tone.

The alarm lights flash.

Over range alarm

If a channel’s gas reading exceeds that channel’s full-scale setting:

OVER displays in the alarm field for that channel.

The channel’s display line flashes.

The buzzer sounds a pulsed tone.

The alarm lights flash.