Updating channel settings – RKI Instruments Eagle Series User Manual

Page 34

Advertising
background image

Diffusion Eagle Instruction Manual

Setup Mode • 29

2. Press the AIR/

or SHIFT/

button to display the desired setting.

CAUTION:

This setting should always match the type of batteries
(alkaline or Ni-Cd) installed in the Eagle. If this setting
does not match the installed batteries, the time between
low battery warning and low battery alarm may be less
than expected.

3. Press the POWER/ENTER button to enter the setting and return to the

main menu.

Updating Channel Settings

This procedure describes how to update channel settings for the combustible
gas, oxygen, and toxic gas channels.

CAUTION:

Verify that the correct sensor is installed before you
update a channel’s settings.

Updating combustible gas channel settings

This section describes how to update the target gas label, set a custom gas
label, and update the full-scale PPM setting for the combustible gas channel.

Updating the target gas label

1. From the main menu, select the GAS COMBINATIONS menu option.

2. Use the AIR/

or SHIFT/

button to place the prompt next to the

combustible gas channel (in this example CH4).

3. Press the POWER/ENTER button. The combustible gas target gas label

flashes. This indicates that this setting can now be updated.

4. Press the AIR/

or SHIFT/

buttons to display the available combustible

gas target gas labels (CH4, HEX, H2, ***, and NOT USED).

NOTE: Select the HEX or *** setting for Methane Elimination

(see “Appendix B: Methane Elimination” on page 58 for more
information.)

C H

4

O

Y

C O

H

2

S

X

>

Advertising