Rockwell Automation 20D PowerFlex 700 Installation Instructions - Frames 7…10 User Manual

Page 42

Advertising
background image

42

Rockwell Automation Publication 20B-IN014H-EN-P - June 2013

PowerFlex 700 Adjustable Frequency AC Drive – Frames 7…10

400 Volt AC Input Protection Devices

(7)

480 Volt AC Input Protection Devices

(7)

Drive Catalog
Number

(6)

Fr

am

e

kW Rating

PWM Freq.

Temp.

(8)

Input Ratings

Output Amps

Dual Element Time
Delay Fuse

Non-Time Delay
Fuse

Circuit
Breaker

(3)

Motor Circuit
Protector

(4)

ND

HD

kHz

°C

Amps

kVA

Cont.

1 Min.

3 Sec.

Min.

(1)

Max.

(2)

Min.

(1)

Max.

(2)

Max.

(5)

Max.

(5)

20BC292

7

160

4

40

293

203

292

322

438

375

650

375

850

850

400

150

4

40

264

183

263

395

526

350

550

350

550

750

400

20BC325

7

180

4

40

326

226

325

358

488

425

700

425

950

950

600

180

4

40

326

226

325

488

650

425

700

425

950

950

600

20BC365

8

200

2

40

366

253

365

402

548

475

800

475

1000

1000

600

180

2

40

326

226

325

488

650

425

700

425

950

950

600

20BC415

8

240

2

40

416

288

415

457

623

525

900

525

1200

1200

600

200

2

40

366

253

365

548

730

475

800

475

1000

1000

600

20BC481

8

280

2

40

483

334

481

530

722

600

1000

600

1400

1400

700

240

2

40

416

288

415

623

830

525

900

525

1200

1200

600

20BC535

8

300

2

40

537

372

535

589

803

700

1200

700

1600

1600

700

280

2

40

483

334

481

722

962

600

1000

600

1400

1400

700

20BC600

8

350

2

40

602

417

600

660

900

750

1300

750

1800

1800

800

300

2

40

537

371

535

803

1070

700

1200

700

1600

1600

700

20BC730

9

400

2

40

702

486

730

803

1095

900

1500

900

2100

2100

900

350

2

40

602

417

600

900

1200

750

1300

750

1800

1800

800

20BC875

10

500

2

40

877

608

875

963

1313

1100

1900

1100

2600

2600

1200

400

2

40

877

486

700

1050

1400

900

1500

900

2100

2100

900

See

page 43

for Notes.

Drive
Catalog
Number

Fr

am

e

Hp Rating

PWM Freq.

Temp.

Input Ratings

Output Amps

Dual Element Time
Delay Fuse

Non-Time Delay
Fuse

Circuit
Breaker

(3)

Motor Circuit
Protector

(4)

ND

HD

kHz

°C

Amps

kVA

Cont.

1 Min.

3 Sec.

Min.

(1)

Max.

(2)

Min.

(1)

Max.

(2)

Max.

(5)

Max.

(5)

20BD292

(6)

7

250

4

40

(8)

281

233

292

322

438

375

650

375

850

850

400

200

4

40

(8)

253

210

263

395

526

350

550

350

550

750

400

20BD325

(6)

7

250

4

40

(8)

313

260

325

358

488

425

700

425

950

950

600

250

4

40

(8)

313

260

325

488

650

425

700

425

950

950

600

20BD365

(6)

8

300

2

40

(8)

351

292

365

402

548

475

800

475

1000

1000

600

250

2

40

(8)

313

260

325

488

650

425

700

425

950

950

600

20BD415

(6)

8

350

2

40

(8)

399

331

415

457

623

525

900

525

1200

1200

600

300

2

40

(8)

351

291

365

548

730

475

800

475

1000

1000

600

20BD481

(6)

8

400

2

40

(8)

462

384

481

530

722

600

1000

600

1400

1400

700

350

2

40

(8)

399

331

415

623

830

525

900

525

1200

1200

600

20BD535

(6)

8

450

2

40

(8)

514

427

535

589

803

700

1200

700

1600

1600

700

400

2

40

(8)

462

384

481

722

962

600

1000

600

1400

1400

700

20BD600

(6)

8

500

2

40

(8)

577

479

600

660

900

750

1300

750

1800

1800

800

450

2

40

(8)

514

427

535

803

1070

700

1200

700

1600

1600

700

20BD730

(6)

9

600

2

40

(8)

673

559

730

803

1095

900

1500

900

2100

2100

900

500

2

40

(8)

577

479

600

900

1200

750

1300

750

1800

1800

800

20BD875

(6)

10

700

2

40

(8)

841

699

875

963

1313

1100

1900

1100

2600

2600

1200

600

2

40

(8)

673

559

700

1050

1400

900

1500

900

2100

2100

900

See

page 43

for Notes.

Advertising