Rockwell Automation Publication 20B-IN014H-EN-P - June 2013

51

PowerFlex 700 Adjustable Frequency AC Drive – Frames 7…10

I/O Terminal Designations

No.

Signal

Fa

ct

or

y

Defa

ult

Description

Re

lat

ed

Pa

ra

m

.

1

Analog In 1 (–)

(1)

(1) Important: 0…20mA operation requires a jumper at terminals 17 & 18 (or 19 & 20). Drive damage can occur if jumper is not

installed.

(3)

(3) These inputs/outputs are dependant on a number of parameters (see “Related Parameters”).

Isolated

(4)

, bipolar, differential, ±10V/4-20mA, 11 bit & sign, 88k

ohm input impedance. For 4-20mA, a jumper must be installed at
terminals 17 & 18 (or 19 & 20).

(4) Differential Isolation - External source must be maintained at less than 160V with respect to PE. Input provides high common mode

immunity.

320…
327

2

Analog In 1 (+)

(1)

3

Analog In 2 (–)

(1)

4

Analog In 2 (+)

(1)

5

Pot Common

For (+) and (–) 10V pot references.

6

Analog Out 1 (–)

(3)

Bipolar (current output is not bipolar), ±10V/4-20mA, 11 bit & sign,
voltage mode - limit current to 5 mA. Current mode - max. load
resistance is 400 ohms.

340…
347

7

Analog Out 1 (+)

8

Analog Out 2 (–)

9

Analog Out 2 (+)

10

HW PTC Input 1

1.8k ohm PTC, Internal 3.32k ohm pull-up resistor

238, 259

11

Digital Out 1 – N.C.

(2)

(2) Contacts in unpowered state. Any relay programmed as Fault or Alarm energizes (picks up) when power is applied to the drive and

deenergizes (drops out) when a fault or alarm exists. Relays selected for other functions energize only when that condition exists
and deenergize when condition is removed.

Fault

Max. Resistive Load:
240V AC/30V DC – 1200VA, 150W
Max. Current: 5A, Min. Load: 10mA
Max. Inductive Load:
240V AC/30V DC – 840VA, 105W
Max. Current: 3.5A, Min. Load: 10mA

380…
391

12

Digital Out 1 Common

13

Digital Out 1 – N.O.

(2)

NOT Fault

14

Digital Out 2 – N.C.

(2)

NOT Run

15

Digital Out 2/3 Com.

16

Digital Out 3 – N.O.

(2)

Run

17

Current In Jumper

(1)

Analog In 1

Placing a jumper across terminals 17 & 18 (or 19 & 20) configures that
analog input for current.

18

19

Current In Jumper

(1)

Analog In 2

20

21

–10V Pot Reference

2k ohm minimum load.

22

+10V Pot Reference

23

HW PTC Input 2

See above

24

+24VDC

(5)

Drive supplied logic input power.

(5)

(5) 150mA maximum Load. Not present on 115V versions.

25

Digital In Common

26

24V Common

(5)

Common for internal power supply.

27

Digital In 1

Stop - CF

115V AC, 50/60 Hz - Control & I/O Cat. No. option D
Opto isolated
Low State: less than 30V AC
High State: greater than 100V AC
24V DC - Control & I/O Cat. No. option C
Opto isolated
Low State: less than 5V DC
High State: greater than 20V DC
11.2 mA DC

361…
366

28

Digital In 2

Start

29

Digital In 3

Auto/Man.

30

Digital In 4

Speed Sel 1

31

Digital In 5

Speed Sel 2

32

Digital In 6/Hardware
Enable, see pg.

54

Speed Sel 3

33

Digital Out 4 – N.C.

Fault

Dedicated fault output - Not user configurable. Relay energizes (picks
up) when power is applied to the drive and deenergizes (drops out)
when a fault exists. See Terminals 11-16 for specs.

34

Digital Out 4 Common

35

Digital Out 4 – N.O.

NOT Fault

PS+

Aux. Control Power (+)

Refer to

page 39

.

PS-

Aux. Control Power (–)

Refer to

page 39

.

PE

PE Ground

PE Ground

PE

PE Ground

PE Ground